Description
Specifications
Rail width W ( mm )
|
A
|
B
|
C
|
75
|
25
|
167.7
|
203.5
|
100
|
50
|
180.2
|
216
|
125
|
75
|
192.7
|
228.5
|
Note1 : The A, B, C dimensions change according to the width of the applicable rail.
?SM-006 /?HM-006 Specifications
Type
|
Single-speed type
|
|
Model
|
For 100V – 115V
|
?SM-006
|
For 200V – 230V
|
?HM-006
|
|
Capacity ( kg )
|
60
|
|
Headroom ( mm ) *
|
425
|
|
Standard lift ( m )
|
3
|
|
Motor output ( kW )
|
0.3
|
|
Lifting speed ( m / min )
|
13
|
|
Traverse motor output ( kW )
|
0.15
|
|
Traversing speed ( m / min : 50 Hz / 60 Hz )
|
10 / 12
|
|
Applicable traverse rail width ( mm )
|
75 ? 100 ? 125
|
|
Minimum traverse turning radius ( mm )
|
900
|
|
Minimum height of traverse rail ( mm )
|
100
|
|
Net weight ( kg )
|
32.5
|
1 ) See here for the specifications for small electric chain hoist.
2 ) *The headroom slightly differs according to the size of the applicable traverse rail.
3 ) The single-phase traverse motor has E-class insulation, and the short time rating is 15 min.
4 ) The power cord of 0.5m extending from the trolley ( 3-core : 1 pc for earth ) is supplied.
2 ) *The headroom slightly differs according to the size of the applicable traverse rail.
3 ) The single-phase traverse motor has E-class insulation, and the short time rating is 15 min.
4 ) The power cord of 0.5m extending from the trolley ( 3-core : 1 pc for earth ) is supplied.
Specifications and dimensions are subject to change without notice.
Catalog
Instruction manual
Rail width W ( mm )
|
A
|
B
|
C
|
75
|
25
|
167.7
|
203.5
|
100
|
50
|
180.2
|
216
|
125
|
75
|
192.7
|
228.5
|
Note1 : The A, B, C dimensions change according to the width of the applicable rail.
?SM-01 /?HM-01 Specifications
Type
|
Single-speed type
|
|
Model
|
For 100V – 115V
|
?SM-01
|
For 200V – 230V
|
?HM-01
|
|
Capacity ( kg )
|
100
|
|
Headroom ( mm ) *
|
425
|
|
Standard lift ( m )
|
3
|
|
Motor output ( kW )
|
0.3
|
|
Lifting speed ( m / min )
|
13
|
|
Traverse motor output ( kW )
|
0.15
|
|
Traversing speed ( m / min : 50 Hz / 60 Hz )
|
10 / 12
|
|
Applicable traverse rail width ( mm )
|
75 ? 100 ? 125
|
|
Minimum traverse turning radius ( mm )
|
900
|
|
Minimum height of traverse rail ( mm )
|
100
|
|
Net weight ( kg )
|
32.5
|
1 ) See here for the specifications for small electric chain hoist.
2 ) *The headroom slightly differs according to the size of the applicable traverse rail.
3 ) The single-phase traverse motor has E-class insulation, and the short time rating is 15 min.
4 ) The power cord of 0.5m extending from the trolley ( 3-core : 1 pc for earth ) is supplied.
2 ) *The headroom slightly differs according to the size of the applicable traverse rail.
3 ) The single-phase traverse motor has E-class insulation, and the short time rating is 15 min.
4 ) The power cord of 0.5m extending from the trolley ( 3-core : 1 pc for earth ) is supplied.
Specifications and dimensions are subject to change without notice.
Catalog
Instruction manual
Rail width W ( mm )
|
A
|
B
|
C
|
75
|
25
|
167.7
|
203.5
|
100
|
50
|
180.2
|
216
|
125
|
75
|
192.7
|
228.5
|
Note1 : The A, B, C dimensions change according to the width of the applicable rail.
?SM-016 /?HM-016 Specifications
Type
|
Single-speed type
|
|
Model
|
For 100V – 115V
|
?SM-016
|
For 200V – 230V
|
?HM-016
|
|
Capacity ( kg )
|
160
|
|
Headroom ( mm ) *
|
425
|
|
Standard lift ( m )
|
3
|
|
Motor output ( kW )
|
0.6
|
|
Lifting speed ( m / min )
|
15
|
|
Traverse motor output ( kW )
|
0.15
|
|
Traversing speed ( m / min : 50 Hz / 60 Hz )
|
10 / 12
|
|
Applicable traverse rail width ( mm )
|
75 ? 100 ? 125
|
|
Minimum traverse turning radius ( mm )
|
900
|
|
Minimum height of traverse rail ( mm )
|
100
|
|
Net weight ( kg )
|
34.5
|
1 ) See here for the specifications for small electric chain hoist.
2 ) *The headroom slightly differs according to the size of the applicable traverse rail.
3 ) The single-phase traverse motor has E-class insulation, and the short time rating is 15 min.
4 ) The power cord of 0.5m extending from the trolley ( 3-core : 1 pc for earth ) is supplied.
2 ) *The headroom slightly differs according to the size of the applicable traverse rail.
3 ) The single-phase traverse motor has E-class insulation, and the short time rating is 15 min.
4 ) The power cord of 0.5m extending from the trolley ( 3-core : 1 pc for earth ) is supplied.
Specifications and dimensions are subject to change without notice.
Catalog
Instruction manual
Rail width W ( mm )
|
A
|
B
|
C
|
75
|
25
|
167.7
|
203.5
|
100
|
50
|
180.2
|
216
|
125
|
75
|
192.7
|
228.5
|
Note1 : The A, B, C dimensions change according to the width of the applicable rail.
?SM-025 /?HM-025 Specifications
Type
|
Single-speed type
|
|
Model
|
For 100V – 115V
|
?SM-025
|
For 200V – 230V
|
?HM-025
|
|
Capacity ( kg )
|
250
|
|
Headroom ( mm ) *
|
425
|
|
Standard lift ( m )
|
3
|
|
Motor output ( kW )
|
0.6
|
|
Lifting speed ( m / min )
|
10
|
|
Traverse motor output ( kW )
|
0.15
|
|
Traversing speed ( m / min : 50 Hz / 60 Hz )
|
10 / 12
|
|
Applicable traverse rail width ( mm )
|
75 ? 100 ? 125
|
|
Minimum traverse turning radius ( mm )
|
900
|
|
Minimum height of traverse rail ( mm )
|
100
|
|
Net weight ( kg )
|
34.5
|
1 ) See here for the specifications for small electric chain hoist.
2 ) *The headroom slightly differs according to the size of the applicable traverse rail.
3 ) The single-phase traverse motor has E-class insulation, and the short time rating is 15 min.
4 ) The power cord of 0.5m extending from the trolley ( 3-core : 1 pc for earth ) is supplied.
2 ) *The headroom slightly differs according to the size of the applicable traverse rail.
3 ) The single-phase traverse motor has E-class insulation, and the short time rating is 15 min.
4 ) The power cord of 0.5m extending from the trolley ( 3-core : 1 pc for earth ) is supplied.
Specifications and dimensions are subject to change without notice.
Catalog
Instruction manual
Rail width W ( mm )
|
A
|
B
|
C
|
75
|
25
|
167.7
|
203.5
|
100
|
50
|
180.2
|
216
|
125
|
75
|
192.7
|
228.5
|
Note1 : The A, B, C dimensions change according to the width of the applicable rail.
?SM-050 /?HM-050 Specifications
Type
|
Single-speed type
|
|
Model
|
For 100V – 115V
|
?SM-050
|
For 200V – 230V
|
?HM-050
|
|
Capacity ( kg )
|
500
|
|
Headroom ( mm ) *
|
505
|
|
Standard lift ( m )
|
3
|
|
Motor output ( kW )
|
0.6
|
|
Lifting speed ( m / min )
|
5
|
|
Traverse motor output ( kW )
|
0.15
|
|
Traversing speed ( m / min : 50 Hz / 60 Hz )
|
10 / 12
|
|
Applicable traverse rail width ( mm )
|
75 ? 100 ? 125
|
|
Minimum traverse turning radius ( mm )
|
900
|
|
Minimum height of traverse rail ( mm )
|
100
|
|
Net weight ( kg )
|
37
|
1 ) See here for the specifications for small electric chain hoist.
2 ) *The headroom slightly differs according to the size of the applicable traverse rail.
3 ) The single-phase traverse motor has E-class insulation, and the short time rating is 15 min.
4 ) The power cord of 0.5m extending from the trolley ( 3-core : 1 pc for earth ) is supplied.
2 ) *The headroom slightly differs according to the size of the applicable traverse rail.
3 ) The single-phase traverse motor has E-class insulation, and the short time rating is 15 min.
4 ) The power cord of 0.5m extending from the trolley ( 3-core : 1 pc for earth ) is supplied.
Specifications and dimensions are subject to change without notice.
Catalog
Instruction manual
Rail width W ( mm )
|
A
|
B
|
C
|
75
|
25
|
167.7
|
203.5
|
100
|
50
|
180.2
|
216
|
125
|
75
|
192.7
|
228.5
|
Note1 : The A, B, C dimensions change according to the width of the applicable rail.
?SBM-006 /?HBM-006 Specifications
Type
|
Dual-speed type
|
|
Model
|
For 100V – 115V
|
?SBM-006
|
For 200V – 230V
|
?HBM-006
|
|
Capacity ( kg )
|
60
|
|
Headroom ( mm ) *
|
425
|
|
Standard lift ( m )
|
3
|
|
Motor output ( kW )
|
0.3
|
|
Lifting speed ( m / min )
|
Low : 5
High : 13 |
|
Traverse motor output ( kW )
|
0.15
|
|
Traversing speed ( m / min : 50 Hz / 60 Hz )
|
10 / 12
|
|
Applicable traverse rail width ( mm )
|
75 ? 100 ? 125
|
|
Minimum traverse turning radius ( mm )
|
900
|
|
Minimum height of traverse rail ( mm )
|
100
|
|
Net weight ( kg )
|
32.5
|
1 ) See here for the specifications for small electric chain hoist.
2 ) *The headroom slightly differs according to the size of the applicable traverse rail.
3 ) The single-phase traverse motor has E-class insulation, and the short time rating is 15 min.
4 ) The power cord of 0.5m extending from the trolley ( 3-core : 1 pc for earth ) is supplied.
2 ) *The headroom slightly differs according to the size of the applicable traverse rail.
3 ) The single-phase traverse motor has E-class insulation, and the short time rating is 15 min.
4 ) The power cord of 0.5m extending from the trolley ( 3-core : 1 pc for earth ) is supplied.
Specifications and dimensions are subject to change without notice.
Catalog
Instruction manual
Rail width W ( mm )
|
A
|
B
|
C
|
75
|
25
|
167.7
|
203.5
|
100
|
50
|
180.2
|
216
|
125
|
75
|
192.7
|
228.5
|
Note1 : The A, B, C dimensions change according to the width of the applicable rail.
?SBM-01 /?HBM-01 Specifications
Type
|
Dual-speed type
|
|
Model
|
For 100V – 115V
|
?SBM-01
|
For 200V – 230V
|
?HBM-01
|
|
Capacity ( kg )
|
100
|
|
Headroom ( mm ) *
|
425
|
|
Standard lift ( m )
|
3
|
|
Motor output ( kW )
|
0.3
|
|
Lifting speed ( m / min )
|
Low : 4
High : 13 |
|
Traverse motor output ( kW )
|
0.15
|
|
Traversing speed ( m / min : 50 Hz / 60 Hz )
|
10 / 12
|
|
Applicable traverse rail width ( mm )
|
75 ? 100 ? 125
|
|
Minimum traverse turning radius ( mm )
|
900
|
|
Minimum height of traverse rail ( mm )
|
100
|
|
Net weight ( kg )
|
32.5
|
1 ) See here for the specifications for small electric chain hoist.
2 ) *The headroom slightly differs according to the size of the applicable traverse rail.
3 ) The single-phase traverse motor has E-class insulation, and the short time rating is 15 min.
4 ) The power cord of 0.5m extending from the trolley ( 3-core : 1 pc for earth ) is supplied.
2 ) *The headroom slightly differs according to the size of the applicable traverse rail.
3 ) The single-phase traverse motor has E-class insulation, and the short time rating is 15 min.
4 ) The power cord of 0.5m extending from the trolley ( 3-core : 1 pc for earth ) is supplied.
Specifications and dimensions are subject to change without notice.
Catalog
Instruction manual
Rail width W ( mm )
|
A
|
B
|
C
|
75
|
25
|
167.7
|
203.5
|
100
|
50
|
180.2
|
216
|
125
|
75
|
192.7
|
228.5
|
Note1 : The A, B, C dimensions change according to the width of the applicable rail.
?SBM-016 /?HBM-016 Specifications
Type
|
Dual-speed type
|
|
Model
|
For 100V – 115V
|
?SBM-016
|
For 200V – 230V
|
?HBM-016
|
|
Capacity ( kg )
|
160
|
|
Headroom ( mm ) *
|
425
|
|
Standard lift ( m )
|
3
|
|
Motor output ( kW )
|
0.6
|
|
Lifting speed ( m / min )
|
Low : 5
High : 15 |
|
Traverse motor output ( kW )
|
0.15
|
|
Traversing speed ( m / min : 50 Hz / 60 Hz )
|
10 / 12
|
|
Applicable traverse rail width ( mm )
|
75 ? 100 ? 125
|
|
Minimum traverse turning radius ( mm )
|
900
|
|
Minimum height of traverse rail ( mm )
|
100
|
|
Net weight ( kg )
|
34.5
|
1 ) See here for the specifications for small electric chain hoist.
2 ) *The headroom slightly differs according to the size of the applicable traverse rail.
3 ) The single-phase traverse motor has E-class insulation, and the short time rating is 15 min.
4 ) The power cord of 0.5m extending from the trolley ( 3-core : 1 pc for earth ) is supplied.
2 ) *The headroom slightly differs according to the size of the applicable traverse rail.
3 ) The single-phase traverse motor has E-class insulation, and the short time rating is 15 min.
4 ) The power cord of 0.5m extending from the trolley ( 3-core : 1 pc for earth ) is supplied.
Specifications and dimensions are subject to change without notice.
Catalog
Instruction manual
Rail width W ( mm )
|
A
|
B
|
C
|
75
|
25
|
167.7
|
203.5
|
100
|
50
|
180.2
|
216
|
125
|
75
|
192.7
|
228.5
|
Note1 : The A, B, C dimensions change according to the width of the applicable rail.
?SBM-025 /?HBM-025 Specifications
Type
|
Dual-speed type
|
|
Model
|
For 100V – 115V
|
?SBM-025
|
For 200V – 230V
|
?HBM-025
|
|
Capacity ( kg )
|
250
|
|
Headroom ( mm ) *
|
425
|
|
Standard lift ( m )
|
3
|
|
Motor output ( kW )
|
0.6
|
|
Lifting speed ( m / min )
|
Low : 4
High : 10 |
|
Traverse motor output ( kW )
|
0.15
|
|
Traversing speed ( m / min : 50 Hz / 60 Hz )
|
10 / 12
|
|
Applicable traverse rail width ( mm )
|
75 ? 100 ? 125
|
|
Minimum traverse turning radius ( mm )
|
900
|
|
Minimum height of traverse rail ( mm )
|
100
|
|
Net weight ( kg )
|
34.5
|
1 ) See here for the specifications for small electric chain hoist.
2 ) *The headroom slightly differs according to the size of the applicable traverse rail.
3 ) The single-phase traverse motor has E-class insulation, and the short time rating is 15 min.
4 ) The power cord of 0.5m extending from the trolley ( 3-core : 1 pc for earth ) is supplied.
2 ) *The headroom slightly differs according to the size of the applicable traverse rail.
3 ) The single-phase traverse motor has E-class insulation, and the short time rating is 15 min.
4 ) The power cord of 0.5m extending from the trolley ( 3-core : 1 pc for earth ) is supplied.
Specifications and dimensions are subject to change without notice.
Catalog
Instruction manual
Rail width W ( mm )
|
A
|
B
|
C
|
75
|
25
|
167.7
|
203.5
|
100
|
50
|
180.2
|
216
|
125
|
75
|
192.7
|
228.5
|
Note1 : The A, B, C dimensions change according to the width of the applicable rail.
?SBM-050 /?HBM-050 Specifications
Type
|
Dual-speed type
|
|
Model
|
For 100V – 115V
|
?SBM-050
|
For 200V – 230V
|
?HBM-050
|
|
Capacity ( kg )
|
500
|
|
Headroom ( mm ) *
|
505
|
|
Standard lift ( m )
|
3
|
|
Motor output ( kW )
|
0.6
|
|
Lifting speed ( m / min )
|
Low : 2
High : 5 |
|
Traverse motor output ( kW )
|
0.15
|
|
Traversing speed ( m / min : 50 Hz / 60 Hz )
|
10 / 12
|
|
Applicable traverse rail width ( mm )
|
75 ? 100 ? 125
|
|
Minimum traverse turning radius ( mm )
|
900
|
|
Minimum height of traverse rail ( mm )
|
100
|
|
Net weight ( kg )
|
37.5
|
1 ) See here for the specifications for small electric chain hoist.
2 ) *The headroom slightly differs according to the size of the applicable traverse rail.
3 ) The single-phase traverse motor has E-class insulation, and the short time rating is 15 min.
4 ) The power cord of 0.5m extending from the trolley ( 3-core : 1 pc for earth ) is supplied.
2 ) *The headroom slightly differs according to the size of the applicable traverse rail.
3 ) The single-phase traverse motor has E-class insulation, and the short time rating is 15 min.
4 ) The power cord of 0.5m extending from the trolley ( 3-core : 1 pc for earth ) is supplied.
Specifications and dimensions are subject to change without notice.
Catalog
Instruction manual