3-phase Constant speed FA/FB Series With Electric Trolley

Category: Brand:

Description

Specifications

FAM-0.5 Dimensions

Figure of FAM-0.5 dimensions

FAM-0.5 Specifications

Model
FAM-0.5
Capacity ( ton )
0.5
Test load ( ton )
0.625
Standard lift ( m )
4
Lifting speed ( m / min )
50 Hz
7.0
60 Hz
8.4
Traversing motor output ( kW )
0.4
Traversing speed
( m / min )
50 Hz / 60 Hz
20 / 24
( MAF type )
50 Hz / 60 Hz
10 / 12
( MAS type )
Headroom ( mm )
695 ( 600 )
I-beam
Width ( mm )
75 ? 100 ? 125 ? 150
Minimum radius ( mm )
1100
Net weight ( kg )
76 ( 77 )
1 ) The number bracketed in “Net weight ( kg )” indicates 6m lift.
2 ) The length of power cord in standard is 4 core-0.5m in case of 4 push button, 7 core-0.5m in case of 6 push button.
3 ) When you need 6 push button for crane instead of 4 push button, ” C ” should be added to the end of model name.
4 ) Short time duty for MAF / MAS is 30 minutes.
5 ) Minimum distance is in case of that “I-beam Width ( mm )” is minimum.
6 ) The number bracketed in “Headroom ( mm )” means direct connection.
Catalog
Instruction manual

FAM-1 Dimensions

Figure of FAM-1 dimensions

FAM-1 Specifications

Model
FAM-1
Capacity ( ton )
1
Test load ( ton )
1.25
Standard lift ( m )
4
Lifting speed ( m / min )
50 Hz
6.3
60 Hz
7.5
Traversing motor output ( kW )
0.4
Traversing speed
( m / min )
50 Hz / 60 Hz
20 / 24
( MAF type )
50 Hz / 60 Hz
10 / 12
( MAS type )
Headroom ( mm )
730 ( 625 )
I-beam
Width ( mm )
75 ? 100 ? 125 ? 150
Minimum radius ( mm )
1100
Net weight ( kg )
91 ( 91 )
1 ) The number bracketed in “Net weight ( kg )” indicates 6m lift.
2 ) The length of power cord in standard is 4 core-0.5m in case of 4 push button, 7 core-0.5m in case of 6 push button.
3 ) When you need 6 push button for crane instead of 4 push button, ” C ” should be added to the end of model name.
4 ) Short time duty for MAF / MAS is 30 minutes.
5 ) Minimum distance is in case of that “I-beam Width ( mm )” is minimum.
6 ) The number bracketed in “Headroom ( mm )” means direct connection.
Catalog
Instruction manual

FAM-2 Dimensions

Figure of FAM-2 dimensions

FAM-2 Specifications

Model
FAM-2
Capacity ( ton )
2
Test load ( ton )
2.5
Standard lift ( m )
4
Lifting speed ( m / min )
50 Hz
3.1
60 Hz
3.8
Traversing motor output ( kW )
0.4
Traversing speed
( m / min )
50 Hz / 60 Hz
20 / 24
( MAF type )
50 Hz / 60 Hz
10 / 12
( MAS type )
Headroom ( mm )
910 ( 750 )
I-beam
Width ( mm )
100 ? 125 ? 150
Minimum radius ( mm )
1500
Net weight ( kg )
117 ( 111 )
1 ) The number bracketed in “Net weight ( kg )” indicates 6m lift.
2 ) The length of power cord in standard is 4 core-0.5m in case of 4 push button, 7 core-0.5m in case of 6 push button.
3 ) When you need 6 push button for crane instead of 4 push button, ” C ” should be added to the end of model name.
4 ) Short time duty for MAF / MAS is 30 minutes.
5 ) Minimum distance is in case of that “I-beam Width ( mm )” is minimum.
6 ) The number bracketed in “Headroom ( mm )” means direct connection.
Catalog
Instruction manual

FAM-3 Dimensions

Figure of FAM-3 dimensions
( H : Headroom )

( mm )

Model
A
B
C
*D
*E
*F
G
I
FAM-3
148
208
239
582
324
( 400 )
252
160
316
Model
*J
K
L
M
N
O
?P ( diameter of wheel )
H
FAM-3
181
60
43
165
49
32
98
1020
( 860 )
1 ) Dimension marked by ” * ” is in case of that “I-beam Width ( mm )” is minimum.

FAM-3 Specifications

Model
FAM-3
Capacity ( ton )
3
Test load ( ton )
3.75
Standard lift ( m )
4
Lifting speed ( m / min )
50 Hz
2.1
60 Hz
2.5
Traversing motor output ( kW )
0.4
Traversing speed
( m / min )
50 Hz / 60 Hz
20 / 24
( MAF type )
50 Hz / 60 Hz
10 / 12
( MAS type )
Headroom ( mm )
1020 ( 860 )
I-beam
Width ( mm )
100 ? 125 ? 150
Minimum radius ( mm )
1500
Net weight ( kg )
147 ( 154 )
1 ) The number bracketed in “Net weight ( kg )” indicates 6m lift.
2 ) The length of power cord in standard is 4 core-0.5m in case of 4 push button, 7 core-0.5m in case of 6 push button.
3 ) When you need 6 push button for crane instead of 4 push button, ” C ” should be added to the end of model name.
4 ) Short time duty for MAF / MAS is 30 minutes.
5 ) Minimum distance is in case of that “I-beam Width ( mm )” is minimum.
6 ) The number bracketed in “Headroom ( mm )” means direct connection.
Catalog
Instruction manual

Specifications

FBM-0.5 Dimensions

Figure of FBM-0.5 dimensions

FBM-0.5 Specifications

Model
FBM-0.5
Capacity ( ton )
0.5
Test load ( ton )
0.625
Standard lift ( m )
4
Lifting speed ( m / min )
( FB ) High : Low speed
50 Hz
7.0 : 1.8
60 Hz
8.4 : 2.1
Traversing motor output ( kW )
0.4
Traversing speed
( m / min )
50 Hz / 60 Hz
20 / 24
( MAF type )
50 Hz / 60 Hz
10 / 12
( MAS type )
Headroom ( mm )
695 ( 600 )
I-beam
Width ( mm )
75 ? 100 ? 125 ? 150
Minimum radius ( mm )
1100
Net weight ( kg )
79 ( 78 )
1 ) The number bracketed in “Net weight ( kg )” indicates 6m lift.
2 ) The length of power cord in standard is 4 core-0.5m in case of 4 push button, 7 core-0.5m in case of 6 push button.
3 ) When you need 6 push button for crane instead of 4 push button, ” C ” should be added to the end of model name.
4 ) Short time duty for MAF / MAS is 30 minutes.
5 ) Minimum distance is in case of that “I-beam Width ( mm )” is minimum.
6 ) The number bracketed in “Headroom ( mm )” means direct connection.
Catalog
Instruction manual

FBM-1 Dimensions

Figure of FAM-1 dimensions

FBM-1 Specifications

Model
FBM-1
Capacity ( ton )
1
Test load ( ton )
1.25
Standard lift ( m )
4
Lifting speed ( m / min )
( FB ) High : Low speed
50 Hz
6.3 : 1.6
60 Hz
7.5 : 1.9
Traversing motor output ( kW )
0.4
Traversing speed
( m / min )
50 Hz / 60 Hz
20 / 24
( MAF type )
50 Hz / 60 Hz
10 / 12
( MAS type )
Headroom ( mm )
730 ( 625 )
I-beam
Width ( mm )
75 ? 100 ? 125 ? 150
Minimum radius ( mm )
1100
Net weight ( kg )
95 ( 92 )
1 ) The number bracketed in “Net weight ( kg )” indicates 6m lift.
2 ) The length of power cord in standard is 4 core-0.5m in case of 4 push button, 7 core-0.5m in case of 6 push button.
3 ) When you need 6 push button for crane instead of 4 push button, ” C ” should be added to the end of model name.
4 ) Short time duty for MAF / MAS is 30 minutes.
5 ) Minimum distance is in case of that “I-beam Width ( mm )” is minimum.
6 ) The number bracketed in “Headroom ( mm )” means direct connection.
Catalog
Instruction manual

FBM-2 Dimensions

Figure of FBM-2 dimensions

FBM-2 Specifications

Model
FBM-2
Capacity ( ton )
2
Test load ( ton )
2.5
Standard lift ( m )
4
Lifting speed ( m / min )
( FB ) High : Low speed
50 Hz
3.1 : 0.8
60 Hz
3.8 : 0.9
Traversing motor output ( kW )
0.4
Traversing speed
( m / min )
50 Hz / 60 Hz
20 / 24
( MAF type )
50 Hz / 60 Hz
10 / 12
( MAS type )
Headroom ( mm )
910 ( 750 )
I-beam
Width ( mm )
100 ? 125 ? 150
Minimum radius ( mm )
1500
Net weight ( kg )
119 ( 112 )
1 ) The number bracketed in “Net weight ( kg )” indicates 6m lift.
2 ) The length of power cord in standard is 4 core-0.5m in case of 4 push button, 7 core-0.5m in case of 6 push button.
3 ) When you need 6 push button for crane instead of 4 push button, ” C ” should be added to the end of model name.
4 ) Short time duty for MAF / MAS is 30 minutes.
5 ) Minimum distance is in case of that “I-beam Width ( mm )” is minimum.
6 ) The number bracketed in “Headroom ( mm )” means direct connection.
Catalog
Instruction manual

FBM-3 Dimensions

Figure of FAM-3 dimensions
( H : Headroom )

( mm )

Model
A
B
C
*D
*E
*F
G
I
FBM-3
148
208
239
582
324
( 400 )
252
160
316
Model
*J
K
L
M
N
O
?P ( diameter of wheel )
H
FBM-3
181
60
43
165
49
32
98
1020
( 860 )
1 ) Dimension marked by ” * ” is in case of that “I-beam Width ( mm )” is minimum.

FBM-3 Specifications

Model
FBM-3
Capacity ( ton )
3
Test load ( ton )
3.75
Standard lift ( m )
4
Lifting speed ( m / min )
( FB ) High : Low speed
50 Hz
2.1 : 0.5
60 Hz
2.5 : 0.6
Traversing motor output ( kW )
0.4
Traversing speed
( m / min )
50 Hz / 60 Hz
20 / 24
( MAF type )
50 Hz / 60 Hz
10 / 12
( MAS type )
Headroom ( mm )
1020 ( 860 )
I-beam
Width ( mm )
100 ? 125 ? 150
Minimum radius ( mm )
1500
Net weight ( kg )
148 ( 155 )
1 ) The number bracketed in “Net weight ( kg )” indicates 6m lift.
2 ) The length of power cord in standard is 4 core-0.5m in case of 4 push button, 7 core-0.5m in case of 6 push button.
3 ) When you need 6 push button for crane instead of 4 push button, ” C ” should be added to the end of model name.
4 ) Short time duty for MAF / MAS is 30 minutes.
5 ) Minimum distance is in case of that “I-beam Width ( mm )” is minimum.
6 ) The number bracketed in “Headroom ( mm )” means direct connection.
Catalog
Instruction manual